Tuesday, January 8, 2013

Heating and Cooling Units - Refrigerant more Healthy.


Heating and Cooling Units - Why do people Prefer it?



The refrigerant R-410A is a blend developed as definitive replacement of R-22 for various OEM applications. For new installations, a team with the right amount of charge and with properly sized pipes, the R-410A has been shown to have an EER (Energy Efficiency Rating-Energy Efficiency Rating-) of 5 to 6% higher than the R-22.



The R-410A also exhibits higher capacity and discharge pressure than R-22, thus allowing the design of air conditioning equipment smaller and more compact. The refrigerant R-410A is also a viable option to replace the R-13B1 in existing equipment of very low temperature.


Home Depot - Chemical Properties.



The R-410A refrigerant is ecological since it contains no chlorine and therefore does not affect the ozone layer. Your greenhouse is equivalent to the R-22. Their superior thermodynamic characteristics allow using more compact compressors, pipes of smaller diameter, higher speeds and more efficient manufacturing equipment because it has a lower energy loss. Working pressures of R-410A is 60% higher than the R-22.



Heating and Cooling Window Units - Security Measures.



The toxicity and flammability characteristics of R-410A are similar to those of R-22. Non-toxic and non-flammable under normal operating conditions. It is not flammable at atmospheric pressure and temperature, but it can get high pressure combustion when mixed with air. Never use air to pressurize a system loaded with any amount of R-410A for leaks.



The R-410A vapor is heavier than air and displaces it if released in a confined space, causing suffocation and unconsciousness. Avoid high heat sources near R-410A vapor as they can produce toxic compounds.


Heating and Cooling Units Prices - Recommendations in the installation of R-410A.



When loading a system with R-410A must be done with great care to minimize the effects of fragmentation of its component refrigerants. The R-410A should be charged as liquid service valve in the suction pipe. The liquid flow must be controlled in the manifold with low pressure valve must ensure that the flow is sufficiently low to prevent ingress of liquid to the compressor.



Use copper tubing clean and dry. The ends of the pipe should be covered to keep moisture. The welding must be carried out by injecting nitrogen into the pipes.